Skip to main content
Hematology analyzer

DxH 690T

Benchtop analyzer for mid-volume labs, up to 100 samples per hour. CBC with differential, reticulocytes, body fluids and MDW.

Brand
Suitable for
Mid-volume laboratories
  • Benchtop analyzer, up to 100 samples per hour
  • CBC with five-part differential, reticulocytes and body fluids (cerebrospinal, serous, synovial)
  • Monocyte Distribution Width (MDW) as an early sepsis indicator, when enabled
  • Enhanced Coulter Principle and VCS 360 with DataFusion characterise cells in a near-native state, with fewer reruns and slide reviews

Technical specifications

Technical specifications of DxH 690T
MethodologyEnhanced Coulter Principle, VCS 360 with DataFusion
ThroughputUp to 100 samples/hour
Sample volumesWhole blood: 165 µL aspiration volume. Predilute: 50 µL whole blood into 200 µL of diluent
CBCWBC, RBC, HGB, HCT, MCV, MCH, MCHC, RDW, RDW-SD, PLT, MPV
DifferentialNE%, LY%, MO%, EO%, BA%, NRBC%, NE#, LY#, MO#, EO#, BA#, NRBC#, MDW (when enabled)
ReticulocytesRET, RET#, MRV, IRF
Body fluids (cerebrospinal, serous, synovial)RBC, TNC
WBC measuring range0.050–400.000 × 10³ cells/µL
RBC measuring range0.005–8.500 × 10⁶ cells/µL
HGB measuring range0.10–25.50 g/dL
MCV measuring range50.00–150.00 fL
RDW measuring range10.00–40.00 %
RDW-SD measuring range15.00–150.00 fL
PLT measuring range3.0–3000.0 × 10³ cells/µL
MPV measuring range5.00–25.00 fL
TNC measuring range (body fluids)20–89,000 cells/mm³
RBC measuring range (body fluids)1,000–6,200,000 cells/mm³
Data managementUp to 50,000 patient results with histograms, scatter plots and demographics; 100,000 patient results with graphics on the Power Computer
Quality assuranceQC with Levey-Jennings graph; XB/XM moving averages; daily check; intelligent quality monitoring; customizable calibration and QC reminders; automatic QC export
Acoustic noise≤ 60 dBA
Electromagnetic compatibilityEN 61326-1, EN 61326-2-6
Power consumptionAnalyzer (SPM): 520 W; monitor: 35 W; DxH Power Computer: 160 W
DimensionsWidth 76.2 cm (30 in); height 90.17 cm (35.5 in) cover closed, 113.03 cm (44.5 in) cover open; depth 83.82 cm (33 in) with the removable back panel, 80 cm (31.5 in) without
WeightAbout 141.97 kg (313 lb) with monitor; about 136.98 kg (302 lb) without
Clearance15.2 cm (6.0 in) per side for troubleshooting; 3.8 cm (1.5 in) behind for cooling
DowntimeMinimum 30 minutes in cleaner every 24 hours, with automatic daily checks

More in this group

DxH 900

Up to 100 samples per hour. CBC with differential, reticulocytes and body fluids.

DxH SlideMaker Stainer II

Automated slide making and staining, with the same sample transport and aspiration technology as the DxH 900.

Request advice on this product

Product: DxH 690T